{"title":"JXCF for Fieldbus IO-Link with STO Function - Incremental Encoder","description":null,"products":[{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-ley-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LEY with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197772927012,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_7d72a154-bee4-4c1d-b145-8759f0e30504.jpg?v=1743162943"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-lef-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LEF with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197772959780,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_e7e78e2c-65d0-4261-bbd2-3b426bb201fa.jpg?v=1743162944"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-leh-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LEH with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197772992548,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_2f03bc69-3cdd-4623-9d18-9d42440b95b6.jpg?v=1743162945"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-les-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LES with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197773025316,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_fdcf72d6-bffb-4e85-92b8-36b2272143d6.jpg?v=1743162945"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-lesh-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LESH with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197773058084,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_1855f389-f9ba-4bfa-bf4c-49c0d7642eb9.jpg?v=1743162948"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-ler-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LER with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197773090852,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_ecb253d3-2bba-45cf-b209-4bcdbf881e01.jpg?v=1743162949"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-lem-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LEM with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197773123620,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_32e2607a-8ac4-4915-a9ed-eba87759286b.jpg?v=1743162950"},{"product_id":"jxc-f-with-sto-function-for-fieldbus-and-io-link-for-lep-with-incremental-encoder","title":"JXC*F with STO Function, for Fieldbus and IO-Link - for LEP with Incremental Encoder","description":"\u003cp\u003eThe JXC*F single axis controller operates LE's 24VDC step motors with incremental or absolute encoders.  The Safe Stop 1 (SS1-t) and Safety Torque Off (STO) sub-functions are included.  Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible via the IO-Link protocol.  Further compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring, and trial runs.\u003c\/p\u003e\n                    \u003cul\u003e\n\u003cli\u003eUp to 64 lines of step data\u003c\/li\u003e\n\u003cli\u003ePositioning and pushing operations\u003c\/li\u003e\n\u003cli\u003eAbsolute and relative movements\u003c\/li\u003e\n\u003cli\u003eFree configuration software required (downloadable)\u003c\/li\u003e\n\u003cli\u003eConnector and 5-pin plug for STO function\u003c\/li\u003e\n\u003cli\u003eConnectors for IO-Link, actuator, power, programming\u003c\/li\u003e\n\u003cli\u003e3 status LED's\u003c\/li\u003e\n\u003c\/ul\u003e \u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/JXC_StepMotor.pdf\" class=\"pdf-button\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":42197773156388,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/8454\/9924\/files\/JXCLF_0623f7ca-6ccf-4816-98ef-4f9be35a40ed.jpg?v=1743162950"}],"url":"https:\/\/hakpneumatic.com\/collections\/jxcf-for-fieldbus-io-link-with-sto-function-incremental-encoder.oembed","provider":"HAK Fluid Power Equipment LTD","version":"1.0","type":"link"}